Question 262 marksVery Short AnswerSection B

An electric kettle is rated 750 W750\ \mathrm{W}; 220 V220\ \mathrm{V}. Can this kettle be used in a circuit which has a fuse of current rating 3 A3\ \mathrm{A}? Give reason for your answer.

Electricity
Electric Power and Fuses

Official answer

No, this kettle cannot be safely used in a circuit protected by a 3 A fuse, because the current it draws under normal operation exceeds 3 A.

Marking scheme

  1. 1.1 mark for correctly calculating I=P/V≈3.4 AI = P/V \approx 3.4~\mathrm{A}
  2. 2.1 mark for correct conclusion (No) with reasoning that current exceeds fuse rating

Analysis and explanation

As explained in the chapter under electric power, P=VIP = VI (Eq. 11.19), so the operating current is I=P/VI = P/V. For the kettle, P=750 WP = 750~\mathrm{W} and V=220 VV = 220~\mathrm{V}:

I=750 W220 V≈3.4 AI = \frac{750~\mathrm{W}}{220~\mathrm{V}} \approx 3.4~\mathrm{A}

The chapter explains the role of a fuse: 'It protects circuits and appliances by stopping the flow of any unduly high electric current... If a current larger than the specified value flows through the circuit, the temperature of the fuse wire increases. This melts the fuse wire and breaks the circuit.' Since the kettle's normal working current (≈3.4 A\approx 3.4~\mathrm{A}) already exceeds the fuse's rated value of 3 A3~\mathrm{A}, the fuse would melt (blow) as soon as the kettle is switched on, even under normal, non-faulty operation. Therefore this kettle cannot be used with a 3 A fuse; a fuse of higher rating (e.g., 5 A, as used for the 1 kW iron example in the chapter) would be needed.

Question details

Q26 of 39 questions

Board
CBSE
Class
Class 10
Subject
Science
Year
2025
Section
Section B
Marks
2
Type
Very Short Answer
Chapter
Electricity
Topic
Electric Power and Fuses
Bloom's level
Apply
Syllabus topic
Heating Effect of Electric Current — Fuse

Spotted a mistake or something unclear?

Tell us and we will fix it.

Frequently asked questions

How many marks does this question carry in CBSE Class 10 Science 2025?

This question carries 2 marks in the CBSE Class 10 Science 2025 examination.

Which chapter does this question come from in Science?

This question is from the chapter "Electricity" in the CBSE Class 10 Science syllabus.

What topic does this question cover in Science?

This question covers the topic "Electric Power and Fuses" from CBSE Class 10 Science.

What type of question is this in the CBSE Class 10 Science 2025 paper?

This is a Very Short Answer question from Section B in the CBSE Class 10 Science 2025 paper.